E. ESC/ THROTTLE control surface movement check
ESC/throttle can be set by DOS setting software or RC controller. First, adjust throttle‘s control movement
on RC controller, roll throttle stick on lowest position, then on SW1, switch ABM to 3D mode 6 times, time
interval has to be less than 3 seconds as follows:
ABM→3DMode→ABM→3DMode→ABM→3DMode→ABM→3DMode→ABM→3D Mode→ABM→3D
Mode, there is a yellow lamp will light up once, it‘s done.
15. Gyroscope Reset
If the following conditions occur, the DOS initialization is recommended:
(1) The device has not been used for a long time.
(2) There is a change in environmental temperature of over 30 degrees since last flight.
(3) The purple LED flashes continuously even when the DOS remains stationary and you never activate the
motor.
Note:
Carry out this re-setting procedure only if the above occur. We do not recommend regular re-setting. It is
not necessary and not recommended.
The stabilizer unit does not need to be in a horizontal position during initialization. However, you must
ensure there is no vibration during this process. If suspect shaking occurred during the procedure, just restart
the initialization / resetting process.
Initialization / Reset Process:
1) Power on and keep stationary.
2) Switch to ABM.
3) On SW1,switch ABM to Deactivated Mode 6 times, time interval has to be less than 3 seconds as follows:
ABM→ Deactivated Mode ABM Deactivated Mode ABM Deactivated Mode → ABM
Deactivated Mode → ABM → Deactivated Mode → ABM → Deactivated Mode.
4) DOS indicator will flash white about one second.
5) After white lamp lights off, the re-setting / initialization is complete.
(If you connect a DOS setup software, you can initialize it by click "Init GYRO" button.)
16. DOS Setting Software: